Lifestyle Start up

 

Initial Startup

WARNING: In order to check for leaks, the following steps are performed without the skirting in place. To prevent risk of electric shock, do not use spa at this time.

1.   Make sure the power supply is OFF.

2.   Check to see that the Black Drain Valve (located to the left rear side of Equipment Module) is closed and that all Barrel Unions are tight.

3.   Fill the spa with water to the center line of the skimmer  (located under the black, removable  skimmer  box  cover).  Always  fill  your  spa  through  the  filter  skimmer. Failure to do so may cause air to be trapped in either pump, preventing the pump from  circulating  water.  Remove  the  hose  and  replace  the  filter  cartridge  as illustrated in the “Filter Maintenance” Section.

IMPORTANT NOTE: The Equipment Module must never be operated without water in the spa, otherwise serious damage to the heater and/or pump could result.

4.   The slice valves on each side of the Equipment Module should be open. (valve is open when the handle is pulled out, closed when it is pushed in).

5.   Check for leaks! Although spas are fully checked at factory, shipping & delivery might cause a leak. Call your Lifestyle Spa dealer directly if there is a problem.

6.   Before  power  is  applied,  refer  to  and  become  familiar  with  the  spa  side  control operations.

7.   Apply power to the Equipment Module.

8.   When your spa is first started, the Pump System will come on and it will go into a priming  mode.  After  displaying  some  configuration  information,  the  electronic control system will perform a self-diagnostic check. This priming mode will last for up to  4 minutes approximately and then both the spa will automatically begin to heat in Standard Mode. This is the default mode that is factory set.

IMPORTANT  NOTE: It is  very important that  the pump  be  operating  for several minutes  to  ensure  that  all  air  has  been  removed  from  the  filtration  system. The thermostat may only be “turned up” after full water flow has been established.

9.   The  Default  pre-set  Temperature  is  37.5°C.  The  last  measured  temperature  is constantly  displayed  on  the  LCD  readout.  This  temperature  will  be  current  only when the pump has been running for at least 2 minutes.

10.   Check for leaks! Although spas are fully checked at factory, shipping & delivery might cause a leak. Remember to pay particular attention to Barrel Unions. Contact your Lifestyle Spa dealer directly if there is a problem.

11.   Add Start-Up Chemicals