Where do I place the conduit for my vortex swim spa?

 

When you are preparing a new base for your swim spa or installing a deck and would like to conceal the power please follow these instructions.

 

Valid on all swim spas made after the 7th of February 2018:

 

Mark out where your spa will sit on the base using the provided dimensions. Measure 1000mm from the touchpad end of the swim spa and 400mm in from the right side of the spa (while facing the key pad end of the swim spa).

 

You can have your electrician run the conduit and cable before the concrete is poured so that is can enter through the base of the swim spa at the noted location which will conceal the power entrance.

NOTE: The conduit should not stick above the concrete more than 150mm.

 

When the swim spa arrives, you will see the 200mm hole in the base of the swim spa which will be covered by insulation. The insulation has a slot in it and the conduit can be pushed up through the insulation as the swim spa is placed.

 

PLEASE NOTE: Most local authorities insists that your swim spa is separated from it's isolation switch by at least 1 metre. Your electrician should be aware of this and should be consulted prior to settling on the exact position of your swim spa.

 

 

 